FEP is a copolymer of tetrafluoroethylene and hexafluoropropylene that can be melt extruded and injection molded. It is a material option for designs combining chemical resistance, electrical insulation and flexibility.
Pellets, films, tubing and wire coatings involve different processing and service conditions. Check grade, melt flow rate, finished thickness and test method together rather than comparing a single typical value.
Explore Material overview and typical properties →Thin FEP sections are more flexible, while thicker sections provide greater structural stiffness. Tensile, flexural and compressive behavior also changes with temperature, specimen geometry and processing history.
Define acceptable strain and dimensional change before assessing the associated stress. Room-temperature tensile strength does not establish elevated-temperature load capacity, and short-term data does not directly predict long-term service.
Explore Mechanical properties →Under a sustained load, FEP can undergo time-dependent deformation known as creep. Under fixed deformation, internal stress can decrease over time through stress relaxation. These involve different boundary conditions.
Evaluate temperature, stress and service duration for seals, clamps, linings and supports. Where dimensions or contact pressure matter, use long-term data for the relevant conditions and verify the finished part.
Explore Creep and stress relaxation →Transverse deformation, repeated flexing and impact represent different mechanical questions. Flex life depends on grade, thickness and test conditions; it is not a universal service-life figure.
For moving tubing, films and components, check bend radius, notches, mounting and temperature. Read test results together with specimen geometry and conditions to make meaningful comparisons.
Explore Poisson’s ratio, fatigue and impact →FEP has a low-friction surface with limited adhesion. Hardness, friction coefficient and wear rate describe different characteristics and cannot substitute for one another.
Sliding contact depends on the counterface, roughness, pressure, speed and temperature. Low friction does not mean zero wear. Bonding applications require a separate assessment of appropriate surface treatment.
Explore Hardness, friction and wear →Melting point, continuous service temperature and thermal expansion describe different behavior. Melting point concerns the melt transition; it is not the continuous operating temperature or load limit of a finished part.
Rising temperature affects stiffness and dimensional stability. Evaluate thermal cycling, mechanical loads, fit tolerances and actual service conditions for hot-service tubing, linings and insulation.
Explore Thermal properties →FEP’s dielectric constant, dielectric loss and insulating characteristics make it a candidate for wire, cable and electronic insulation. Interpret each property using its corresponding test method.
Dielectric strength depends on thickness, specimen quality and test conditions. High-frequency selection also requires frequency and temperature checks. Material data does not replace finished cable or assembly verification.
Explore Electrical properties →FEP is a candidate for many chemical-contact applications, including tubing and equipment linings. Compatibility must address the actual medium, concentration, exposure duration and temperature.
Also assess mixed chemicals, mechanical stress, connections and seal materials. An unchanged appearance does not establish the absence of permeation or the suitability of the complete system.
Explore Chemical resistance →Absorption describes a medium entering the material; permeation involves its passage through the material. Both differ from chemical attack. Low water absorption does not mean all gases and liquids are blocked.
For films, tubing and outdoor parts, evaluate thickness, temperature, medium and exposure. Weathering tests in the supplied source describe reference materials, not a guaranteed outdoor lifetime for Everflon™ products.
Explore Absorption, permeability and weathering →FEP can be considered for low-temperature and optical applications. Mechanical behavior must still be checked against temperature, loading and part geometry. Cryogenic service and liquid-oxygen compatibility are separate questions.
Film transmission depends on thickness, wavelength, surface and processing. Validate optical requirements with representative samples. Food-contact and special-media applications also require suitable grade-specific documentation.
Explore Low-temperature and optical properties →FEP can be melt processed by extrusion and injection molding. Resin flow, equipment configuration and finished geometry must work together to establish a suitable process window.
Thin-wall wire coatings, tubing and molded parts have different needs. Set temperature, residence time and cooling according to grade data and equipment, then establish quality control through dimensional and finished-part checks.
Explore Melt processing and forming →FEP can be machined, but flexibility, heat transfer and deformation affect workholding and cut quality. Plan tool condition, support and chip removal around the part geometry.
Do not apply a single fixed cutting speed or feed to every job. Avoid excessive clamping and local heat buildup; use trial machining to assess burrs, surface finish and dimensional recovery.
Explore Machining and tooling →FEP dimensions are influenced by temperature, machining stresses and measurement technique. Plan tolerances for service conditions and control measurement temperature and contact force to avoid distorting flexible parts.
Assess annealing, finishing and cleaning for the application. Follow the actual grade’s safety data sheet and equipment procedures, including appropriate ventilation and temperature control.