Electrical Properties
The text reports a dielectric constant of about 2.04–2.05 from 1 kHz to 13 GHz. Dissipation factor rises from 0.00006 at 1 kHz to 0.0006 at 30 MHz, with a stated peak near 0.001 at about 1 GHz.
Temperature significantly affects loss, although curve shapes are similar. The author's expectation of similar values across its own grades does not establish equivalence across manufacturers.
| Item | Frequency | Value |
|---|---|---|
| Dielectric constant | 1kHz–13GHz | Approx. 2.04–2.05 |
| Dissipation factor | 1kHz | 0.00006 |
| Dissipation factor | 30MHz | 0.0006 |
| Loss peak, as stated in text | Approx. 1 GHz | Approx. 0.001 |
Frequency Effect
Approximate source redraw; not measured 4610 data.
Approximate source redraw; not measured 4610 data.
Temperature Effect
Figures 22–23 compare 21°C, 100°C and 150°C. Read temperature together with frequency; higher temperature does not necessarily increase or decrease loss at every frequency.
Approximate source redraw; not measured 4610 data.
Approximate source redraw; not measured 4610 data.
Source data, charts and compliance statements concern another manufacturer’s reference material. Renaming a grade does not establish equivalence or measured performance for Everflon FEP 4610. Curves are approximate illustrations, not engineering input. · Product and Properties Handbook: Electrical Properties; Frequency Effect; Temperature Effect