Material properties and applications of FEP

FEP films combine broad chemical resistance, high and low temperature adaptability, non-stick and low friction properties, as well as excellent weather resistance, optical and electrical properties. The material contains no plasticizers or additives and can be processed using normal thermoplastic materials.

Chemical Resistant Protection and Formed Parts

Can be used in membranes, gaskets, protective liners and thermoformed bags or containers. Chemical media, temperature, pressure and mechanical loads must also be taken into consideration during the assessment.

Optical and outdoor use

The high light transmittance and weather resistance properties are suitable for use in environmental growth chambers, solar collectors, and radome windows; the surface treatment type must be separately confirmed for outdoor applicability.

electrical insulation

Can be used for flexible flat cable insulation, printed circuits and electronic components. Film thickness, electrode form, frequency and temperature all affect insulation design.

Release and low friction

The non-stick surface can be used for coating release films, conveyor belts and process rollers. The release effect should be verified based on actual contact materials, surface conditions and processing cycles.

Membranes, gaskets, protective liners and thermoformed bags or containers can take advantage of their chemical and temperature resistance; growth chambers, solar collectors and radome windows combine optical and weather resistance properties. Electrical applications include flexible flat cable insulation, printed circuits and electronic components for computers and aircraft.

If the demand is towards higher temperatures, PFA film can be used as a comparison direction for the highest 260°C use demand; if the emphasis is on toughness and resistance to tear propagation, ETFE film can be compared. Actual selection still requires checking the product specifications of each material.

TECHYOURS™ FEP FILM · 03

Film type and thickness specifications

The thickness reference range for FEP films is 12.5–500 µm (0.5–20 mil). Depending on the film thickness, the upper limit of the customized strip width is 1.2–1.6 m. The roll material can use 7.6 cm or 15.2 cm core. Film thickness, treated surface and size should be confirmed when ordering.

Table 1|FEP film type and thickness comparison
Gauge5010017520030050075010002000
Thickness(mil)0.511.752357.51020
Thickness (µm)12.525445075125190250500
Approximate area factor (ft²/lb)18090514530181294.5
General purpose type A●●●●●●●●●
Single-sided adhesive type C—●●●●●———
Double-sided adhesive type C-20—●—●—●———

● It means that the combination is listed in the technical data; it does not mean that it is in stock or Techyours's supply commitment. The area coefficient is an approximate value, retains the imperial units, and does not use the metric numbers as a basis for conversion doubts.

Each roll of film should be clearly marked with resin type, film thickness and film type. For example, "FEP/500 gauge/C" means FEP resin, 5 mil thickness, and one side can be bonded; this combination is an example of specification marking, not a new product brand.

TECHYOURS™ FEP FILM · 04

Mechanical and Thermal Properties Across a Wide Temperature Range

The reference temperature range of FEP film for continuous use is −240 to 205°C, and for intermittent use up to 260°C. Continuous use, intermittent exposure and processing temperatures are different conditions and are not interchangeable.

Tensile properties

The relationship between tensile stress and elongation changes with temperature. From cryogenic temperatures to high temperatures, FEP films still retain usable mechanical properties; the actual design should be evaluated based on strength, yield, and modulus at the operating temperature, and avoid estimating based on room temperature values alone.

Table 2|Typical mechanical properties of FEP film
ProjectASTM test methodsTypical value
tensile strength at breakASTM D88221 MPa
Elongation at breakASTM D882300%
Yield stressASTM D88212 MPa
elastic modulusASTM D882480 MPa
Stress that produces 5% strainASTM D88212 MPa
MIT folding endurance timesASTM D217610,000 times
Initial tear strength (Graves)ASTM D10045.3 N
Tear propagation strength (Elmendorf)ASTM D19222.5 N
Bursting strengthASTM D77476 kPa
DensityASTM D15052,150 kg/m³
Dynamic friction coefficient (film vs. steel)ASTM D18940.3

Except for the burst strength, which uses 100 gauge (approximately 25 µm) film, the 200 gauge (approximately 50 µm) film is used as the benchmark.

Dimensional stability

The dimensional stability of the film includes three aspects: hygroscopic expansion, residual shrinkage and thermal expansion. The water absorption rate is lower than 0.01% when completely immersed in water, so changes in relative humidity have little impact on the film.

Residual shrinkage

Stresses from manufacturing or subsequent processing can cause unconstrained films to shrink when exposed to high temperatures. After the stress is released by high temperature exposure and shrinkage, the same residual shrinkage no longer occurs under conditions lower than the processing temperature.

thermal expansion

After the residual shrinkage is eliminated, the film will still expand and contract with temperature according to normal thermal expansion behavior; its thermal expansion coefficient increases with temperature. Therefore, gaps, tensions and fixation methods during thermal cycles should be included in the structural design.

Table 3|Typical thermal properties of FEP films
ProjectMethod/ConditionsTypical value
melting pointASTM D3418(DTA)260–280°C
Maximum continuous use temperature—205°C
zero intensity temperatureConditions for withstanding 0.14 MPa load 5 seconds255°C
Thermal conductivity—0.195 W/(m·K)
linear expansion coefficientASTM D6969.4 × 10⁻⁵ /°C
Thin film combustion classification referenceANSI/UL 94VTM-0
oxygen indexASTM D286395%
Dimensional stability150°C, 30 minutesMD expansion 0.7%; TD contraction 2.2%

Based on 200 gauge film. The zero intensity temperature is the temperature at which the film withstands a load of 0.14 MPa for 5 seconds. MD: machine direction; TD: transverse direction. Combustion classification is a material reference and does not represent certification of actual supplied products.

Figure 1|Techyours FEP Film|Relationship between tensile stress and elongation

The tensile stress at the same elongation varies with temperature; this figure retains four curves: −52, 25, 100 and 200°C.

Tensile stress (psi) | Right axis: Tensile stress (MPa)

       0100020003000400050006000050100150200250300350071421283542Elongation (%)
 −52°C 25°C 100°C 200°C

Strain rate: 100%/minute.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 2|Techyours FEP Film|Tensile properties change with temperature

Tensile modulus, tensile strength and yield stress all decrease with increasing temperature.

Stress/modulus (psi, logarithmic scale) | Right axis: MPa (logarithmic scale)

     1001000100001000001e+06-200-328-150-238-100-148-50-58032501221002121503022003922504823005720.77707007000Temperature (°C; °F below)
 Tensile modulus tensile strength Yield stress

The ends of the curve are close to the melting region; the ends do not indicate usable operating temperatures.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 3|Techyours FEP Film|Tensile stress comparison in low elongation zone

The main image compares the 0–30% elongation range; also retains the small elongation, high stress illustration of the −195°C cryogenic specimen.

Tensile stress (psi) | Right axis: MPa

      01000200030004000500001020300714212835Elongation (%)
 −52°C 25°C 100°C 200°C −195°C (rising outside the range of the main picture)

Tensile stress (psi)

   20,00010,000000.5Elongation (%)
 −195°C: enlarged illustration

Cryogenic illustrations are listed separately; 20,000 psi approximately corresponds to 140 MPa, and 10,000 psi approximately corresponds to 70 MPa.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 4|Techyours FEP Film|25 µm Dimensional changes and temperature of general FEP film

Transverse shrinkage and mechanical expansion are presented separately; the positive and negative directions of the original image are retained to avoid misjudgment of expansion as contraction.

Size change (%; positive value shrinks, negative value expands)

        121086420−2 (expansion)6014080176100212120248140284160320180356200392220428240464260500Temperature (°C; °F below)
 TD transverse shrinkage MD mechanical direction expansion

General purpose type, nominal 100 gauge/1 mil/25 µm.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 5|Techyours FEP Film|Thermal expansion of FEP film

After eliminating residual shrinkage, the film will still expand with temperature; the curve is steeper in the high-temperature region.

Linear expansion (%)

       02468101250122100212150302200392250482300572Temperature (°C; °F below)
 linear expansion

The illustrated reference intervals of 265°C (510°F) and 271°C (520°F) are retained; the expansion rate increases in the high temperature zone.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

TECHYOURS™ FEP FILM · 05

Electrical performance: maintains low losses over a wide range of temperatures and frequencies

FEP films have good electrical properties over a wide temperature and frequency range, making them suitable for designs requiring low dielectric loss and insulation stability.

Table 4|25 µm (1 mil) film typical electrical properties
ProjectTest methods/conditionsTypical value
Dielectric strengthASTM D149; in air, 60 Hz, 6.4 mm electrode260 kV/mm
Dielectric constantASTM D150;1 kHz2.0
Dielectric loss factorASTM D150;1 kHz0.0002
Volume resistivityASTM D2571 × 10¹⁸ Ω·cm
surface resistivityASTM D2571 × 10¹⁶ Ω/□
Surface arc resistance timeASTM D495>165 seconds

The arc-resistant sample melted but no traces were formed. Volume resistivity is expressed in Ω·cm to avoid mixing different units.

Dielectric strength

The dielectric strength is related to the film thickness. Thinner films have higher dielectric strength per unit thickness. The voltage resistance design must still consider the total film thickness and actual electric field distribution.

Dielectric constant

The dielectric constant is not affected by film thickness, and there is no difference between general type A and single-sided adhesive type C. At a fixed frequency, the dielectric constant will decrease with temperature due to thermal expansion; at a fixed temperature, it will decrease slightly when the frequency is higher than 10⁷ Hz.

Dielectric loss factor

FEP films have low dielectric dissipation factors over a wide range of temperatures and frequencies, making them suitable for applications where electrical losses are kept to a minimum. Values will still vary with test conditions and cannot be considered fixed under all conditions.

Volume resistivity and insulation resistance

The volume resistivity decreases slightly as the film thickness increases. The reference value of insulation resistance under 200°C is 65,000 MΩ·µF, which shows that it still has good insulation properties at high temperatures.

Figure 6|Techyours FEP Film|Dielectric strength and film thickness

The dielectric strength per unit thickness decreases as the film thickness increases; the curve coordinates retain the non-equidistant scale of the original image.

Dielectric strength (V/mil) | Right axis: kV/mm

      10,0008,0006,0004,0002,0001,0000.512.51252503754100615082001025015375205004003202401608040Film thickness (mil; the following is µm; non-equidistant scale according to the original figure)
 Dielectric strength

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 7|Techyours FEP Film|Dielectric constant and temperature

Under the fixed frequency conditions of 1 kHz and 100 kHz, the dielectric constant gradually decreases as the temperature increases.

Dielectric constant

      1.81.92.02.12.22.3-50-5803250122100212150302200392Temperature (°C; °F below)
 1 kHz and 100 kHz

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 8|Techyours FEP Film|Dielectric constant and frequency

The low frequency to mid-to-high frequency range is relatively stable, above about 10⁷ Hz and then gradually decreases.

Dielectric constant

    2.0202.0102.0052.00010110210310410510610710810910101011Frequency (Hz, logarithmic scale)
 25°C

Fixed temperature 25°C; curve plotted to approximately 10¹⁰ Hz.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 9|Techyours FEP Film|Dielectric loss factor and temperature

Two sets of test conditions, 10⁶ Hz and 10³ Hz, are retained to show the change of low loss factor with temperature.

Dielectric loss factor

     00.00040.00080.00120.0016-50-5803250122100212150302200392250482Temperature (°C; °F below)
 1 × 10⁶ Hz 1 × 10³ Hz

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 10|Techyours FEP Film|Dielectric loss factor and frequency

At a fixed 25°C, the loss factor increases with frequency, appears with a broad peak near the GHz region, and then decreases.

Dielectric dissipation factor (logarithmic scale)

   0.010.0010.000110510610710810910101011Frequency (Hz, logarithmic scale)
 25°C

The measured values of 1 × 10², 10³, and 10⁴ Hz are all lower than 0.0001, which is outside the lower limit of the vertical axis of this figure.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 11|Techyours FEP Film|Volume resistivity and film thickness at 175°C

Comparison of volume resistivity and film thickness retains 175°C test conditions, juxtaposing Ω·cm and Ω·m scales.

Volume resistivity (Ω·cm, logarithmic scale) | Right axis: Ω·m

           10¹⁹8 × 10¹⁸6 × 10¹⁸4 × 10¹⁸2 × 10¹⁸10¹⁸8 × 10¹⁷6 × 10¹⁷4 × 10¹⁷2 × 10¹⁷10¹⁷12525041006150820010250153752050010¹⁷10¹⁶10¹⁵Film thickness (mil; listed in µm; logarithmic scale)
 175°C

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 12|Techyours FEP Film|Insulation resistance and temperature

The insulation resistance decreases as the temperature rises, but remains high near 200°C.

Insulation resistance (MΩ·µF, logarithmic scale)

                10,000,0004,000,0002,000,0001,000,000400,000200,000100,00040,00020,00010,0004,0002,0001,00040020010025775012275167100212125257150302175347200392Temperature (°C; °F below)
 Insulation resistance

This chart is for comparison of temperature effects and does not specify the design film thickness based on it; the insulation performance of individual film thicknesses must be confirmed based on product data and testing.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

TECHYOURS™ FEP FILM · 06

Chemical Properties: Broad Tolerance and Applicable Boundaries

FEP films are highly chemically inert and resistant to a wide range of chemicals and solvents. Exceptions include molten alkali metals, high-temperature fluorine gas, and certain halogenated compounds such as chlorine trifluoride at high temperatures and pressures.

When approaching the upper limit of continuous use 205°C, 80% sodium hydroxide, metal hydrides, aluminum chloride, ammonia and some amines (R–NH₂) may corrode the film in a manner similar to molten alkali metals. Strongly reducing or strongly oxidizing environments require specialized testing.

Table 5|FEP film has record resistance to chemical media
Media nameEnglish identification name
Abietic acidAbietic acid
acetic acidAcetic acid
acetic anhydrideAcetic anhydride
acetoneAcetone
AcetophenoneAcetophenone
Acrylic anhydrideAcrylic anhydride
Allyl acetateAllyl acetate
Allyl methacrylateAllyl methacrylate
aluminum chlorideAluminum chloride
liquid ammoniaAmmonia, liquid
Ammonium chlorideAmmonium chloride
AnilineAniline
BenzonitrileBenzonitrile
benzoyl chlorideBenzoyl chloride
Benzyl alcoholBenzyl alcohol
BoraxBorax
Boric acidBoric acid
BromineBromine
n-butylaminen-Butyl amine
Butyl acetateButyl acetate
Butyl methacrylateButyl methacrylate
calcium chlorideCalcium chloride
carbon disulfideCarbon disulfide
HexadecaneCetane
ChlorineChlorine
ChloroformChloroform
Chlorosulfonic acidChlorosulfonic acid
Chromic acidChromic acid
cyclohexaneCyclohexane
cyclohexanoneCyclohexanone
dibutyl phthalateDibutyl phthalate
Dibutyl sebacateDibutyl sebacate
diethyl carbonateDiethyl carbonate
EtherDiethyl ether
dimethylformamideDimethyl formamide
Diisobutyl adipateDi-isobutyl adipate
dimethylformamideDimethylformamide
TrimethylhydrazineDimethylhydrazine, unsymmetrical
dioxaneDioxane
Ethyl acetateEthyl acetate
ethanolEthyl alcohol
EtherEthyl ether
Ethyl hexanoateEthyl hexoate
DibromoethaneEthylene bromide
Ethylene glycolEthylene glycol
ferric chlorideFerric chloride
iron phosphateFerric phosphate
FluoronaphthaleneFluoronaphthalene
FluoronitrobenzeneFluoronitrobenzene
FormaldehydeFormaldehyde
Formic acidFormic acid
FuransFurane
gasolineGasoline
HexachloroethaneHexachlorethane
Hexane/hydrazine (name to be confirmed)Hexane Hydrazine
hydrochloric acidHydrochloric acid
hydrofluoric acidHydrofluoric acid
hydrogen peroxideHydrogen peroxide
leadLead
magnesium chlorideMagnesium chloride
mercuryMercury
ButanoneMethyl ethyl ketone
methacrylic acidMethacrylic acid
MethanolMethanol
Methyl methacrylateMethyl methacrylate
NaphthaleneNaphthalene
naphtholNaphthols
Nitric acidNitric acid
NitrobenzeneNitrobenzene
2-Nitrobutanol2-Nitro-butanol
NitromethaneNitromethane
dinitrogen tetroxideNitrogen tetroxide
2-nitro-2-methyl propanol2-Nitro-2-methyl propanol
n-stearyl alcoholn-Octadecyl alcohol
Animal and vegetable oilsOils, animal and vegetable
OzoneOzone
perchlorethylenePerchlorethylene
PentachlorobenzamidePentachlorobenzamide
PerfluoroxylenePerfluoroxylene
PhenolPhenol
Phosphoric acidPhosphoric acid
Phosphorus pentachloridePhosphorus pentachloride
Phthalic acidPhthalic acid
PinenePinene
Nitrogen-containing cyclic compounds (name to be confirmed)Piperidene
polyacrylonitrilePolyacrylonitrile
Potassium acetatePotassium acetate
potassium hydroxidePotassium hydroxide
Potassium permanganatePotassium permanganate
PyridinePyridine
Soaps and detergentsSoap and detergents
sodium hydroxideSodium hydroxide
sodium hypochloriteSodium hypochlorite
sodium peroxideSodium peroxide
Aliphatic and aromatic solventsSolvents, aliphatic and aromatic
Stannous chlorideStannous chloride
SulfurSulfur
sulfuric acidSulfuric acid
TetrabromoethaneTetrabromoethane
TetrachlorethyleneTetrachlorethylene
trichloroacetic acidTrichloracetic acid
trichlorethyleneTrichlorethylene
tricresyl phosphateTricresyl phosphate
TriethanolamineTriethanolamine
vinyl methacrylateVinyl methacrylate
waterWater
xyleneXylene
zinc chlorideZinc chloride

The test of each liquid covers conditions up to its boiling point, but the normal operating temperature of FEP is still based on the maximum 205°C. Not included does not necessarily mean there will be a reaction; some halogenated solvents may cause moderate swelling. Media designation does not replace confirmation of compatibility of concentration, temperature and usage conditions.

The final selection in harsh environments should be based on functional testing under actual usage conditions or existing usage experience, and cannot be judged solely by the name of the chemical.

TECHYOURS™ FEP FILM · 07

Physical Properties: Low absorption and quantifiable penetration

absorb

The tiny spaces between plastic molecules can accommodate contact media without necessarily causing a chemical reaction, which often manifests as a slight weight increase and occasionally discoloration. FEP films have very low absorption compared to other thermoplastics.

Very low absorption of common acids and bases under exposure conditions up to 200°C and up to one year. The amount of solvent absorbed is also small, and the weight increase after long-term high temperature exposure is usually less than 1%. The absorption of aqueous solutions is generally very low; the typical water absorption rate under normal temperature and pressure is lower than 0.01%.

penetration

The FEP film's transmission rate to many gases and vapors is lower than that of many thermoplastics, but it does not represent a complete barrier. The amount of penetration usually increases with the increase of temperature, pressure and contact area, and decreases with the increase of film thickness.

Table 6|25 µm film typical gas transmission rate
gascm³/(m²·24 h·atm)
carbon dioxide25.9 × 10³
Hydrogen34.1 × 10³
Nitrogen5.0 × 10³
oxygen11.6 × 10³

When converting to values per 100 in², multiply by 0.0645. Test temperatures are not listed in the table.

Table 7|25 µm film typical vapor transmission rate
Vapor/mediumTemperature (°C)g/(m²·day)
acetic acid356.3
acetone3514.7
Benzene359.9
carbon tetrachloride354.8
Ethyl acetate3511.7
ethanol3510.7
Dichlorodifluoromethane (R-12)23372.0
Hexane358.7
hydrochloric acid25<0.2
red fuming nitric acid25160.0
50% sodium hydroxide25<0.2
98% sulfuric acid252 × 10⁻⁴
water39.57.0

Method: Modified ASTM E96. The pressure of each medium is the vapor pressure at that temperature. Values are average references and do not constitute specification limits.

Film thickness comparison for water vapor transmission rate based on 40°C, modified ASTM E96 conditions. Gas permeability, vapor permeability and liquid absorption must be clearly distinguished for barrier purposes and should not be substituted for each other.

Figure 13|Techyours FEP Film|Water vapor transmission rate and film thickness at 40°C

The water vapor transmittance decreases as the film thickness increases; this chart retains imperial area units to avoid confusion with the metric transmittance table.

Transmittance [g/(100 in²·24 h)]

         00.050.10.150.20.250.30.350.4002504100615082001025012300Film thickness (mil; µm below)
 40°C water vapor transmission rate

Test method: Modified ASTM E96. When converting to g/(m²·24 h), multiply by 15.5.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

TECHYOURS™ FEP FILM · 08

Optical Performance: Lets light pass through high-performance films.

FEP film can transmit a high proportion of ultraviolet light and visible light, and is more transparent to infrared light than glass. Spectral transmittance, film thickness and light incident angle will all affect the actual optical performance.

Solar transmittance

96%ASTM E424 Typical reference values. This value cannot be regarded as the same transmittance at all wavelengths, film thicknesses and angles.

refractive index

1.341–1.347ASTM D542 Typical range. Optical applications must also confirm surface quality, contamination and actual spectral requirements.

Figure 14|Techyours FEP Film|Spectral transmittance of FEP film

The visible light and part of the ultraviolet light region have high transmittance; there are obvious absorption bands in the infrared light region, and the transmittance is not the same at all wavelengths.

Transmittance (%)

           01020304050607080901000.20.61.01.41.82.23.05.07.09.01216203050Wavelength (µm; non-equidistant scale according to original image)
 Spectral transmittance

The curve is captured from the line position of the published image; the absorption valley in the infrared region is retained and is not smoothed into a single high transmittance curve.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 15|Techyours FEP Film|Solar radiation transmittance and film thickness at normal incidence

As the film thickness increases, the transmittance of vertically incident solar radiation gradually decreases.

solar radiation transmittance

         0.840.860.880.90.920.940.960.981000000000000000000000000001111111111111111111111111122222222222222222222222222333333333333333333333333334444444444444444444444444455555555555555555555555555666666666666666666666666667777777777777777777777777788888888888888888888888888Film thickness (mil; µm below)
 vertical incidence

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

Figure 16|Techyours FEP Film|25 µm Solar Radiation Transmittance and Incident Angle of Film

The transmittance remains relatively stable at low to moderate angles of incidence, and decreases as it approaches large angles of incidence; the curve is only drawn to about 75°.

solar radiation transmittance

      00.20.40.60.810153045607590Incident angle (degrees)
 25 µm/1 mil film

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

TECHYOURS™ FEP FILM · 09

Other properties: cryogenic, mold and weather resistant

Cryogenic use

FEP has demonstrated usable performance in cryogenic environments below liquid nitrogen temperatures. Films that are clean and do not contain pigments or reinforcing fillers are generally inert to liquid oxygen; designs involving liquid oxygen still require special compatibility and safety assessments.

Mold resistant

Moisture test of mixed spore inoculation, as well as three-month soil burial test, showed that FEP has good resistance to mold growth. This property does not equate to germicidal or antimicrobial certification.

Weather resistance

General FEP films have excellent UV resistance and outdoor stability. Existing long-term outdoor exposure data records that 20 has no obvious discoloration, UV light deterioration or strength loss after years; this is a material reference record, not a product warranty period.

Surface treatment type restrictions

It is not recommended to use Type C and Type C-20 glue-treatable types directly for outdoor use, as UV light may affect the treated surface. Outdoor designs should confirm actual surface preparation and bonding systems.

Figure 17|Techyours FEP Film|The effect of Florida outdoor exposure on FEP film

Two subplots of tensile strength and elongation are retained, as well as changes in film thickness over approximately 20 years of outdoor exposure.

Tensile strength (psi; vertical axis includes broken axis) | Right axis: MPa

   3,0002,0000 (broken shaft)0246810121416182021140Outdoor exposure time (years)
 All film thicknesses: tensile strength upper edge All film thicknesses: tensile strength lower curve 1 All film thicknesses: tensile strength lower curve 2

The tensile strength subgraph retains the broken axis arrangement; the curve below does not have a line-by-line film thickness label, and no additional film thickness is specified.

Elongation (%)

       010020030040050060002468101214161820Outdoor exposure time (years)
 20 mil (approximately 500 µm) 5–10 mil(125–250 µm) 2 mil(50 µm) 1 mil(25 µm)

This is a reference for outdoor exposure of general-type films; it does not extend to outdoor use guarantees for types whose surfaces can be glued, nor does it extend to the product warranty period.

Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.

TECHYOURS™ FEP FILM · 10

Safety and handling

Unheated FEP is essentially inert. Existing animal tests have shown no irritation or sensitization to the skin; dust generated by cutting, grinding or mechanical processing should still be avoided, and exposure should be controlled in accordance with applicable workplace regulations.

Contamination of tobacco or cigarettes with fluoropolymers should be avoided. When processing and using high temperatures, appropriate ventilation must be provided; ventilation and exhaust are especially required when the processing temperature reaches 275°C or above. This temperature is not the dividing line between safe and unsafe, nor is it a recommended processing setting.

Please check the applicable safety data sheet for product use and handling. Without special evaluation, it shall not be used for permanent human implantation or in contact with body fluids and tissues.

The values on this page are typical technical references for FEP films and do not serve as specification limits or independent design basis, nor do they represent the actual measured values or certifications of individual Techyours products. Please refer to the confirmed product information for actual supply, thickness, processing methods and performance.

INQUIRY

  • Afghanistan
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antarctica
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • China
  • Christmas Island
  • Cocos (Keeling) Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Cote D'Ivoire
  • Croatia
  • Cuba
  • Cyprus
  • Czech Republic
  • Denmark
  • Djibouti
  • Dominica
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands (Malvinas)
  • Faroe Islands
  • Fiji
  • Finland
  • France, Metropolitan
  • French Guiana
  • French Polynesia
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Honduras
  • Hong Kong,China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran (Islamic Republic of)
  • Iraq
  • Ireland
  • Israel
  • Italy
  • Jamaica
  • Japan
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • North Korea
  • South Korea
  • Kuwait
  • Kyrgyzstan
  • Lao People's Democratic Republic
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Libyan Arab Jamahiriya
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Micronesia
  • Moldova
  • Monaco
  • Mongolia
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russian Federation
  • Rwanda
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Vincent and the Grenadines
  • Samoa
  • San Marino
  • Saudi Arabia
  • Senegal
  • Seychelles
  • Sierra Leone
  • Singapore
  • Slovak Republic
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • Spain
  • Sri Lanka
  • St. Helena
  • Sudan
  • Suriname
  • Swaziland
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • Taiwan, China
  • Tajikistan
  • Tanzania
  • Thailand
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks and Caicos Islands
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • Uruguay
  • Uzbekistan
  • Vanuatu
  • Vatican City State (Holy See)
  • Venezuela
  • Viet Nam
  • Virgin Islands (U.S.)
  • Wallis and Futuna Islands
  • Western Sahara
  • Yemen
  • Zambia
  • Zimbabwe
  • Montenegro
  • Serbia
  • Palestine
  • South Sudan
  • Jersey