Techyours™ FEP Film Properties and Selection Guide
TECHYOURS™ FEP FILM · 01
Chemically, temperature-resistant, transparent and electrically insulating, combined with an easy-to-process film form.
Techyours™ FEP Film is FEP fluorinated ethylene propylene copolymer film. FEP films can be heat-sealed, thermoformed, welded, metallized, laminated with a variety of materials, or used as a hot-melt bonding layer, making it easier to introduce material properties into actual component design.
From diaphragms, gaskets and protective liners, to transparent windows, electrical insulation and process releases, film forms offer diverse design and processing possibilities.
TECHYOURS™ FEP FILM · 02
FEP films combine broad chemical resistance, high and low temperature adaptability, non-stick and low friction properties, as well as excellent weather resistance, optical and electrical properties. The material contains no plasticizers or additives and can be processed using normal thermoplastic materials.
Can be used in membranes, gaskets, protective liners and thermoformed bags or containers. Chemical media, temperature, pressure and mechanical loads must also be taken into consideration during the assessment.
The high light transmittance and weather resistance properties are suitable for use in environmental growth chambers, solar collectors, and radome windows; the surface treatment type must be separately confirmed for outdoor applicability.
Can be used for flexible flat cable insulation, printed circuits and electronic components. Film thickness, electrode form, frequency and temperature all affect insulation design.
The non-stick surface can be used for coating release films, conveyor belts and process rollers. The release effect should be verified based on actual contact materials, surface conditions and processing cycles.
Membranes, gaskets, protective liners and thermoformed bags or containers can take advantage of their chemical and temperature resistance; growth chambers, solar collectors and radome windows combine optical and weather resistance properties. Electrical applications include flexible flat cable insulation, printed circuits and electronic components for computers and aircraft.
If the demand is towards higher temperatures, PFA film can be used as a comparison direction for the highest 260°C use demand; if the emphasis is on toughness and resistance to tear propagation, ETFE film can be compared. Actual selection still requires checking the product specifications of each material.
TECHYOURS™ FEP FILM · 03
The thickness reference range for FEP films is 12.5–500 µm (0.5–20 mil). Depending on the film thickness, the upper limit of the customized strip width is 1.2–1.6 m. The roll material can use 7.6 cm or 15.2 cm core. Film thickness, treated surface and size should be confirmed when ordering.
| Gauge | 50 | 100 | 175 | 200 | 300 | 500 | 750 | 1000 | 2000 |
|---|---|---|---|---|---|---|---|---|---|
| Thickness(mil) | 0.5 | 1 | 1.75 | 2 | 3 | 5 | 7.5 | 10 | 20 |
| Thickness (µm) | 12.5 | 25 | 44 | 50 | 75 | 125 | 190 | 250 | 500 |
| Approximate area factor (ft²/lb) | 180 | 90 | 51 | 45 | 30 | 18 | 12 | 9 | 4.5 |
| General purpose type A | ● | ● | ● | ● | ● | ● | ● | ● | ● |
| Single-sided adhesive type C | — | ● | ● | ● | ● | ● | — | — | — |
| Double-sided adhesive type C-20 | — | ● | — | ● | — | ● | — | — | — |
● It means that the combination is listed in the technical data; it does not mean that it is in stock or Techyours's supply commitment. The area coefficient is an approximate value, retains the imperial units, and does not use the metric numbers as a basis for conversion doubts.
Each roll of film should be clearly marked with resin type, film thickness and film type. For example, "FEP/500 gauge/C" means FEP resin, 5 mil thickness, and one side can be bonded; this combination is an example of specification marking, not a new product brand.
TECHYOURS™ FEP FILM · 04
The reference temperature range of FEP film for continuous use is −240 to 205°C, and for intermittent use up to 260°C. Continuous use, intermittent exposure and processing temperatures are different conditions and are not interchangeable.
The relationship between tensile stress and elongation changes with temperature. From cryogenic temperatures to high temperatures, FEP films still retain usable mechanical properties; the actual design should be evaluated based on strength, yield, and modulus at the operating temperature, and avoid estimating based on room temperature values alone.
| Project | ASTM test methods | Typical value |
|---|---|---|
| tensile strength at break | ASTM D882 | 21 MPa |
| Elongation at break | ASTM D882 | 300% |
| Yield stress | ASTM D882 | 12 MPa |
| elastic modulus | ASTM D882 | 480 MPa |
| Stress that produces 5% strain | ASTM D882 | 12 MPa |
| MIT folding endurance times | ASTM D2176 | 10,000 times |
| Initial tear strength (Graves) | ASTM D1004 | 5.3 N |
| Tear propagation strength (Elmendorf) | ASTM D1922 | 2.5 N |
| Bursting strength | ASTM D774 | 76 kPa |
| Density | ASTM D1505 | 2,150 kg/m³ |
| Dynamic friction coefficient (film vs. steel) | ASTM D1894 | 0.3 |
Except for the burst strength, which uses 100 gauge (approximately 25 µm) film, the 200 gauge (approximately 50 µm) film is used as the benchmark.
The dimensional stability of the film includes three aspects: hygroscopic expansion, residual shrinkage and thermal expansion. The water absorption rate is lower than 0.01% when completely immersed in water, so changes in relative humidity have little impact on the film.
Stresses from manufacturing or subsequent processing can cause unconstrained films to shrink when exposed to high temperatures. After the stress is released by high temperature exposure and shrinkage, the same residual shrinkage no longer occurs under conditions lower than the processing temperature.
After the residual shrinkage is eliminated, the film will still expand and contract with temperature according to normal thermal expansion behavior; its thermal expansion coefficient increases with temperature. Therefore, gaps, tensions and fixation methods during thermal cycles should be included in the structural design.
| Project | Method/Conditions | Typical value |
|---|---|---|
| melting point | ASTM D3418(DTA) | 260–280°C |
| Maximum continuous use temperature | — | 205°C |
| zero intensity temperature | Conditions for withstanding 0.14 MPa load 5 seconds | 255°C |
| Thermal conductivity | — | 0.195 W/(m·K) |
| linear expansion coefficient | ASTM D696 | 9.4 × 10⁻⁵ /°C |
| Thin film combustion classification reference | ANSI/UL 94 | VTM-0 |
| oxygen index | ASTM D2863 | 95% |
| Dimensional stability | 150°C, 30 minutes | MD expansion 0.7%; TD contraction 2.2% |
Based on 200 gauge film. The zero intensity temperature is the temperature at which the film withstands a load of 0.14 MPa for 5 seconds. MD: machine direction; TD: transverse direction. Combustion classification is a material reference and does not represent certification of actual supplied products.
The tensile stress at the same elongation varies with temperature; this figure retains four curves: −52, 25, 100 and 200°C.
Tensile stress (psi) | Right axis: Tensile stress (MPa)
Strain rate: 100%/minute.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
Tensile modulus, tensile strength and yield stress all decrease with increasing temperature.
Stress/modulus (psi, logarithmic scale) | Right axis: MPa (logarithmic scale)
The ends of the curve are close to the melting region; the ends do not indicate usable operating temperatures.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
The main image compares the 0–30% elongation range; also retains the small elongation, high stress illustration of the −195°C cryogenic specimen.
Tensile stress (psi) | Right axis: MPa
Tensile stress (psi)
Cryogenic illustrations are listed separately; 20,000 psi approximately corresponds to 140 MPa, and 10,000 psi approximately corresponds to 70 MPa.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
Transverse shrinkage and mechanical expansion are presented separately; the positive and negative directions of the original image are retained to avoid misjudgment of expansion as contraction.
Size change (%; positive value shrinks, negative value expands)
General purpose type, nominal 100 gauge/1 mil/25 µm.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
After eliminating residual shrinkage, the film will still expand with temperature; the curve is steeper in the high-temperature region.
Linear expansion (%)
The illustrated reference intervals of 265°C (510°F) and 271°C (520°F) are retained; the expansion rate increases in the high temperature zone.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
TECHYOURS™ FEP FILM · 05
FEP films have good electrical properties over a wide temperature and frequency range, making them suitable for designs requiring low dielectric loss and insulation stability.
| Project | Test methods/conditions | Typical value |
|---|---|---|
| Dielectric strength | ASTM D149; in air, 60 Hz, 6.4 mm electrode | 260 kV/mm |
| Dielectric constant | ASTM D150;1 kHz | 2.0 |
| Dielectric loss factor | ASTM D150;1 kHz | 0.0002 |
| Volume resistivity | ASTM D257 | 1 × 10¹⁸ Ω·cm |
| surface resistivity | ASTM D257 | 1 × 10¹⁶ Ω/□ |
| Surface arc resistance time | ASTM D495 | >165 seconds |
The arc-resistant sample melted but no traces were formed. Volume resistivity is expressed in Ω·cm to avoid mixing different units.
The dielectric strength is related to the film thickness. Thinner films have higher dielectric strength per unit thickness. The voltage resistance design must still consider the total film thickness and actual electric field distribution.
The dielectric constant is not affected by film thickness, and there is no difference between general type A and single-sided adhesive type C. At a fixed frequency, the dielectric constant will decrease with temperature due to thermal expansion; at a fixed temperature, it will decrease slightly when the frequency is higher than 10⁷ Hz.
FEP films have low dielectric dissipation factors over a wide range of temperatures and frequencies, making them suitable for applications where electrical losses are kept to a minimum. Values will still vary with test conditions and cannot be considered fixed under all conditions.
The volume resistivity decreases slightly as the film thickness increases. The reference value of insulation resistance under 200°C is 65,000 MΩ·µF, which shows that it still has good insulation properties at high temperatures.
The dielectric strength per unit thickness decreases as the film thickness increases; the curve coordinates retain the non-equidistant scale of the original image.
Dielectric strength (V/mil) | Right axis: kV/mm
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
Under the fixed frequency conditions of 1 kHz and 100 kHz, the dielectric constant gradually decreases as the temperature increases.
Dielectric constant
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
The low frequency to mid-to-high frequency range is relatively stable, above about 10⁷ Hz and then gradually decreases.
Dielectric constant
Fixed temperature 25°C; curve plotted to approximately 10¹⁰ Hz.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
Two sets of test conditions, 10⁶ Hz and 10³ Hz, are retained to show the change of low loss factor with temperature.
Dielectric loss factor
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
At a fixed 25°C, the loss factor increases with frequency, appears with a broad peak near the GHz region, and then decreases.
Dielectric dissipation factor (logarithmic scale)
The measured values of 1 × 10², 10³, and 10⁴ Hz are all lower than 0.0001, which is outside the lower limit of the vertical axis of this figure.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
Comparison of volume resistivity and film thickness retains 175°C test conditions, juxtaposing Ω·cm and Ω·m scales.
Volume resistivity (Ω·cm, logarithmic scale) | Right axis: Ω·m
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
The insulation resistance decreases as the temperature rises, but remains high near 200°C.
Insulation resistance (MΩ·µF, logarithmic scale)
This chart is for comparison of temperature effects and does not specify the design film thickness based on it; the insulation performance of individual film thicknesses must be confirmed based on product data and testing.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
TECHYOURS™ FEP FILM · 06
FEP films are highly chemically inert and resistant to a wide range of chemicals and solvents. Exceptions include molten alkali metals, high-temperature fluorine gas, and certain halogenated compounds such as chlorine trifluoride at high temperatures and pressures.
When approaching the upper limit of continuous use 205°C, 80% sodium hydroxide, metal hydrides, aluminum chloride, ammonia and some amines (R–NH₂) may corrode the film in a manner similar to molten alkali metals. Strongly reducing or strongly oxidizing environments require specialized testing.
| Media name | English identification name |
|---|---|
| Abietic acid | Abietic acid |
| acetic acid | Acetic acid |
| acetic anhydride | Acetic anhydride |
| acetone | Acetone |
| Acetophenone | Acetophenone |
| Acrylic anhydride | Acrylic anhydride |
| Allyl acetate | Allyl acetate |
| Allyl methacrylate | Allyl methacrylate |
| aluminum chloride | Aluminum chloride |
| liquid ammonia | Ammonia, liquid |
| Ammonium chloride | Ammonium chloride |
| Aniline | Aniline |
| Benzonitrile | Benzonitrile |
| benzoyl chloride | Benzoyl chloride |
| Benzyl alcohol | Benzyl alcohol |
| Borax | Borax |
| Boric acid | Boric acid |
| Bromine | Bromine |
| n-butylamine | n-Butyl amine |
| Butyl acetate | Butyl acetate |
| Butyl methacrylate | Butyl methacrylate |
| calcium chloride | Calcium chloride |
| carbon disulfide | Carbon disulfide |
| Hexadecane | Cetane |
| Chlorine | Chlorine |
| Chloroform | Chloroform |
| Chlorosulfonic acid | Chlorosulfonic acid |
| Chromic acid | Chromic acid |
| cyclohexane | Cyclohexane |
| cyclohexanone | Cyclohexanone |
| dibutyl phthalate | Dibutyl phthalate |
| Dibutyl sebacate | Dibutyl sebacate |
| diethyl carbonate | Diethyl carbonate |
| Ether | Diethyl ether |
| dimethylformamide | Dimethyl formamide |
| Diisobutyl adipate | Di-isobutyl adipate |
| dimethylformamide | Dimethylformamide |
| Trimethylhydrazine | Dimethylhydrazine, unsymmetrical |
| dioxane | Dioxane |
| Ethyl acetate | Ethyl acetate |
| ethanol | Ethyl alcohol |
| Ether | Ethyl ether |
| Ethyl hexanoate | Ethyl hexoate |
| Dibromoethane | Ethylene bromide |
| Ethylene glycol | Ethylene glycol |
| ferric chloride | Ferric chloride |
| iron phosphate | Ferric phosphate |
| Fluoronaphthalene | Fluoronaphthalene |
| Fluoronitrobenzene | Fluoronitrobenzene |
| Formaldehyde | Formaldehyde |
| Formic acid | Formic acid |
| Furans | Furane |
| gasoline | Gasoline |
| Hexachloroethane | Hexachlorethane |
| Hexane/hydrazine (name to be confirmed) | Hexane Hydrazine |
| hydrochloric acid | Hydrochloric acid |
| hydrofluoric acid | Hydrofluoric acid |
| hydrogen peroxide | Hydrogen peroxide |
| lead | Lead |
| magnesium chloride | Magnesium chloride |
| mercury | Mercury |
| Butanone | Methyl ethyl ketone |
| methacrylic acid | Methacrylic acid |
| Methanol | Methanol |
| Methyl methacrylate | Methyl methacrylate |
| Naphthalene | Naphthalene |
| naphthol | Naphthols |
| Nitric acid | Nitric acid |
| Nitrobenzene | Nitrobenzene |
| 2-Nitrobutanol | 2-Nitro-butanol |
| Nitromethane | Nitromethane |
| dinitrogen tetroxide | Nitrogen tetroxide |
| 2-nitro-2-methyl propanol | 2-Nitro-2-methyl propanol |
| n-stearyl alcohol | n-Octadecyl alcohol |
| Animal and vegetable oils | Oils, animal and vegetable |
| Ozone | Ozone |
| perchlorethylene | Perchlorethylene |
| Pentachlorobenzamide | Pentachlorobenzamide |
| Perfluoroxylene | Perfluoroxylene |
| Phenol | Phenol |
| Phosphoric acid | Phosphoric acid |
| Phosphorus pentachloride | Phosphorus pentachloride |
| Phthalic acid | Phthalic acid |
| Pinene | Pinene |
| Nitrogen-containing cyclic compounds (name to be confirmed) | Piperidene |
| polyacrylonitrile | Polyacrylonitrile |
| Potassium acetate | Potassium acetate |
| potassium hydroxide | Potassium hydroxide |
| Potassium permanganate | Potassium permanganate |
| Pyridine | Pyridine |
| Soaps and detergents | Soap and detergents |
| sodium hydroxide | Sodium hydroxide |
| sodium hypochlorite | Sodium hypochlorite |
| sodium peroxide | Sodium peroxide |
| Aliphatic and aromatic solvents | Solvents, aliphatic and aromatic |
| Stannous chloride | Stannous chloride |
| Sulfur | Sulfur |
| sulfuric acid | Sulfuric acid |
| Tetrabromoethane | Tetrabromoethane |
| Tetrachlorethylene | Tetrachlorethylene |
| trichloroacetic acid | Trichloracetic acid |
| trichlorethylene | Trichlorethylene |
| tricresyl phosphate | Tricresyl phosphate |
| Triethanolamine | Triethanolamine |
| vinyl methacrylate | Vinyl methacrylate |
| water | Water |
| xylene | Xylene |
| zinc chloride | Zinc chloride |
The test of each liquid covers conditions up to its boiling point, but the normal operating temperature of FEP is still based on the maximum 205°C. Not included does not necessarily mean there will be a reaction; some halogenated solvents may cause moderate swelling. Media designation does not replace confirmation of compatibility of concentration, temperature and usage conditions.
The final selection in harsh environments should be based on functional testing under actual usage conditions or existing usage experience, and cannot be judged solely by the name of the chemical.
TECHYOURS™ FEP FILM · 07
The tiny spaces between plastic molecules can accommodate contact media without necessarily causing a chemical reaction, which often manifests as a slight weight increase and occasionally discoloration. FEP films have very low absorption compared to other thermoplastics.
Very low absorption of common acids and bases under exposure conditions up to 200°C and up to one year. The amount of solvent absorbed is also small, and the weight increase after long-term high temperature exposure is usually less than 1%. The absorption of aqueous solutions is generally very low; the typical water absorption rate under normal temperature and pressure is lower than 0.01%.
The FEP film's transmission rate to many gases and vapors is lower than that of many thermoplastics, but it does not represent a complete barrier. The amount of penetration usually increases with the increase of temperature, pressure and contact area, and decreases with the increase of film thickness.
| gas | cm³/(m²·24 h·atm) |
|---|---|
| carbon dioxide | 25.9 × 10³ |
| Hydrogen | 34.1 × 10³ |
| Nitrogen | 5.0 × 10³ |
| oxygen | 11.6 × 10³ |
When converting to values per 100 in², multiply by 0.0645. Test temperatures are not listed in the table.
| Vapor/medium | Temperature (°C) | g/(m²·day) |
|---|---|---|
| acetic acid | 35 | 6.3 |
| acetone | 35 | 14.7 |
| Benzene | 35 | 9.9 |
| carbon tetrachloride | 35 | 4.8 |
| Ethyl acetate | 35 | 11.7 |
| ethanol | 35 | 10.7 |
| Dichlorodifluoromethane (R-12) | 23 | 372.0 |
| Hexane | 35 | 8.7 |
| hydrochloric acid | 25 | <0.2 |
| red fuming nitric acid | 25 | 160.0 |
| 50% sodium hydroxide | 25 | <0.2 |
| 98% sulfuric acid | 25 | 2 × 10⁻⁴ |
| water | 39.5 | 7.0 |
Method: Modified ASTM E96. The pressure of each medium is the vapor pressure at that temperature. Values are average references and do not constitute specification limits.
Film thickness comparison for water vapor transmission rate based on 40°C, modified ASTM E96 conditions. Gas permeability, vapor permeability and liquid absorption must be clearly distinguished for barrier purposes and should not be substituted for each other.
The water vapor transmittance decreases as the film thickness increases; this chart retains imperial area units to avoid confusion with the metric transmittance table.
Transmittance [g/(100 in²·24 h)]
Test method: Modified ASTM E96. When converting to g/(m²·24 h), multiply by 15.5.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
TECHYOURS™ FEP FILM · 08
FEP film can transmit a high proportion of ultraviolet light and visible light, and is more transparent to infrared light than glass. Spectral transmittance, film thickness and light incident angle will all affect the actual optical performance.
96%ASTM E424 Typical reference values. This value cannot be regarded as the same transmittance at all wavelengths, film thicknesses and angles.
1.341–1.347ASTM D542 Typical range. Optical applications must also confirm surface quality, contamination and actual spectral requirements.
The visible light and part of the ultraviolet light region have high transmittance; there are obvious absorption bands in the infrared light region, and the transmittance is not the same at all wavelengths.
Transmittance (%)
The curve is captured from the line position of the published image; the absorption valley in the infrared region is retained and is not smoothed into a single high transmittance curve.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
As the film thickness increases, the transmittance of vertically incident solar radiation gradually decreases.
solar radiation transmittance
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
The transmittance remains relatively stable at low to moderate angles of incidence, and decreases as it approaches large angles of incidence; the curve is only drawn to about 75°.
solar radiation transmittance
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
TECHYOURS™ FEP FILM · 09
FEP has demonstrated usable performance in cryogenic environments below liquid nitrogen temperatures. Films that are clean and do not contain pigments or reinforcing fillers are generally inert to liquid oxygen; designs involving liquid oxygen still require special compatibility and safety assessments.
Moisture test of mixed spore inoculation, as well as three-month soil burial test, showed that FEP has good resistance to mold growth. This property does not equate to germicidal or antimicrobial certification.
General FEP films have excellent UV resistance and outdoor stability. Existing long-term outdoor exposure data records that 20 has no obvious discoloration, UV light deterioration or strength loss after years; this is a material reference record, not a product warranty period.
It is not recommended to use Type C and Type C-20 glue-treatable types directly for outdoor use, as UV light may affect the treated surface. Outdoor designs should confirm actual surface preparation and bonding systems.
Two subplots of tensile strength and elongation are retained, as well as changes in film thickness over approximately 20 years of outdoor exposure.
Tensile strength (psi; vertical axis includes broken axis) | Right axis: MPa
The tensile strength subgraph retains the broken axis arrangement; the curve below does not have a line-by-line film thickness label, and no additional film thickness is specified.
Elongation (%)
This is a reference for outdoor exposure of general-type films; it does not extend to outdoor use guarantees for types whose surfaces can be glued, nor does it extend to the product warranty period.
Approximate curves drawn based on technical images for trend reading; not original test points and not used as a basis for specifications or precise interpolation.
TECHYOURS™ FEP FILM · 10
Unheated FEP is essentially inert. Existing animal tests have shown no irritation or sensitization to the skin; dust generated by cutting, grinding or mechanical processing should still be avoided, and exposure should be controlled in accordance with applicable workplace regulations.
Contamination of tobacco or cigarettes with fluoropolymers should be avoided. When processing and using high temperatures, appropriate ventilation must be provided; ventilation and exhaust are especially required when the processing temperature reaches 275°C or above. This temperature is not the dividing line between safe and unsafe, nor is it a recommended processing setting.
Please check the applicable safety data sheet for product use and handling. Without special evaluation, it shall not be used for permanent human implantation or in contact with body fluids and tissues.
The values on this page are typical technical references for FEP films and do not serve as specification limits or independent design basis, nor do they represent the actual measured values or certifications of individual Techyours products. Please refer to the confirmed product information for actual supply, thickness, processing methods and performance.
INQUIRY