Low dielectric constant (Dk)
Lower effective Dk can allow thinner insulation and a smaller diameter for a given electrical design.
High-Speed Data Center Cable Material Selection
Everflon™ · Choose FEP or PFA for the insulation your cable needs
Start with three applications: foamed primary insulation for compact AI rack cables, solid primary insulation for low-loss designs with more room, and outer skin layers.
Explore applicationsLower effective Dk can allow thinner insulation and a smaller diameter for a given electrical design.
Low Df helps reduce dielectric loss at high frequencies. Verify insertion loss on the finished cable.
Compare FEP and PFA candidates against the actual operating temperature.
Assess resistance to moisture and chemicals for the intended service environment.
Foamed insulation calls for control of line speed, the processing window and foaming consistency.
Insulation Structure
| Item | Foam Insulation | Solid Insulation |
|---|---|---|
| Outer Diameter | Ideal for designs prioritizing smaller outer diameters | Suitable for designs with relaxed outer diameter constraints |
| Effective Dk | Foam structure helps reduce effective Dk | Effective Dk is typically higher for solid structures of the same resin |
| Signal Loss | Ideal for compact designs aimed at reducing high-frequency dielectric loss | Low Df grades can be selected to maintain signal performance |
| Application Scenarios | High-density wiring and space-constrained AI server racks | Cables with ample space prioritizing process simplification or durability |
| Process Focus | Foam ratio, cell distribution, and outer diameter stability | Insulation dimensions and extrusion quality |
Skin Layer: Material selection for the skin layer should be separated from the primary insulation layer. FEP4630 can serve as a skin layer candidate and can also be evaluated for solid insulation designs with less stringent electrical requirements.
| Grade | Base resin | Insulation role | Dk | Df | Primary use |
|---|---|---|---|---|---|
| PF4630 | FEP | Foamed insulation | Best | Better | Small-diameter cables for dense AI racks · High foam levels and predictable extrusion. |
| PF430 | PFA | Foamed insulation | Best | Best | Small-diameter cables for dense AI racks · Higher-temperature candidate for compact foamed cables. |
| FEP 4640X | FEP | Solid insulation | Good | Better | Low-loss AI cables with less restrictive diameter limits · Low Df and reliable extrusion. |
| FEP 4630 | FEP | Skin layer and baseline solid insulation | Good | Good | High-speed cable skin layers and less demanding data center cable designs · Typically a skin layer. Also a candidate for less demanding solid designs. |
| PFA 440 | PFA | Solid insulation | Good | Better to best | Low-loss AI cables with less restrictive diameter limits · Low Df with a higher operating-temperature requirement. |
Dk and Df are qualitative selection categories. Verify dielectric performance, operating temperature and extrusion conditions against Everflon™ grade data and finished-cable tests.
01 · Foamed primary insulation
PF4630 is the FEP candidate for high foam levels and predictable extrusion. Evaluate PFA grade PF430 when the compact design also calls for a higher operating temperature.
02 · Solid primary insulation
Evaluate FEP 4640X for low dielectric loss and reliable extrusion. Consider PFA 440 when the solid design also requires a higher operating temperature.
03 · Skin layer and baseline solid insulation
FEP 4630 is typically used as a skin layer. It can also be evaluated as solid insulation in less demanding designs. Select the skin separately from the primary insulation.
Technical consultation
Share these details with the Everflon™ technical team to discuss candidate grades and trial conditions.
Conductor size, insulation thickness and target cable diameter
Operating temperature and service environment
Target frequencies, test length and insertion-loss requirements
Intended insulation structure and extrusion conditions