Everflon™ FEP Grade Selection for Wire and Cable

Everflon™ · FEP

Everflon™ FEP Grade Selection for Wire and Cable

From primary insulation to cable jackets: compare conductor size, extrusion speed and stress-crack resistance.

FEP wire and cable grade selection table
Cross-section schematic. Left: primary insulation. Right: multicore cable jacket.

02 · FEP

Introduction to FEP wire and cable selection

This guide helps cable processors and end users select FEP grades for their equipment, processing conditions and intended applications.

03 · FEP

FEP resin properties and cable uses

FEP is a melt-processable fluoropolymer used in wire insulation and cable jacketing. It combines dielectric and thermal performance with toughness, flexibility, chemical inertness, low friction, release properties, very low moisture uptake, low flammability and weather resistance.

04 · FEP

Grade selection and melt flow rate (MFR)

The grades differ in molecular weight and composition. Higher molecular weight generally improves mechanical performance and stress-crack resistance at the expense of processing speed. The reference temperature rating is 205 °C (401 °F, ISO 2578). Confirm grade and finished-cable ratings against applicable technical data and tests. Table 1 compares typical MFR, relative extrusion speed and stress-crack resistance. MFR references include ISO 12086 and ASTM D2116.

05 Technical Guide

Cable Stress Crack Resistance & Mandrel Wrap Test

Stress cracking occurs when materials form cracks under internal or external stress. Stresses may remain from processing or develop due to repeated thermal cycling or mechanical forces. Exposure to crack-promoting media or insulation damage can aggravate the condition.

Stress crack resistance of finished products can be evaluated using mandrel wrap tests, such as MIL-W-22759 for aerospace wire and ISO 6722/LV112 for automotive wire. Film MIT flex endurance tests based on ASTM D2176 can assist in comparing the crack resistance of resins and wire insulation. Materials with higher MIT flex life generally perform better in mandrel wrap tests.

Conditions That May Increase Crack Risk

  • Large conductor diameters and thick insulation walls.

  • Contact with low surface tension liquids, such as silicone oils and hydrocarbon fluids.

  • Repeated thermal cycling, non-circular or irregular surfaces, and additives.

  • Mechanical actions such as vibration and bending.

  • Resin degradation during processing and melt fracture during extrusion.

  • Melt temperatures that are too low or unevenly distributed, causing cold drawing.

06 Technical Guide

FEP Cable Extrusion Processing

Good manufacturing management is the foundation of high-quality cable coating. Among the factors affecting stress crack resistance in finished products, thermal degradation of the resin and melt fracture deserve particular attention.

Melt Temperature, Residence Time, and Shear

Resin degradation during processing reduces insulation performance in demanding applications. Excessive melt temperatures, prolonged residence time inside the extruder, or high screw shear can all contribute to degradation. An MFR increase exceeding 10% should generally be avoided during extrusion.

In thermal residence comparisons, an MFR increase of about 10% is observed after 5–10 minutes at 390°C or 20 minutes at 380°C, while 60 minutes of residence at 360°C leads to an increase of about 5%. These conditions illustrate thermal degradation trends. Proper resin flow should be maintained at operating temperatures. During brief downtime, equipment temperatures should be adjusted based on the specific grade processing data to minimize residence degradation.

07 · FEP

FEP wire and cable grade selection table

1 · FEP wire and cable grade selection table
Cable coating performance
Everflon™ FEP grade463046224610X461046084603
MFR (g/10 min)30229753
Extrusion speed
HigherLower
Stress-crack resistanceFairFairVery goodGoodVery goodExcellent
Typical conductor diameter<1 mm<1.5 mm1–6 mm1–2 mm2–7 mm>4 mm
Primary insulation
Everflon™ FEP grade4622 / 463046104608 / 4610X
Signal, control and instrumentationAWG 18 or finer, up to about 1.0–1.5 mmAWG 12 or finer, up to about 2.0 mmCoarser than AWG 18, above about 1.0 mm*
Power cableNot typical*Not typical*Up to AWG 4, about 6–7 mm
Appliance wireUp to about 1.5 mm*Not typical*Not typical*
Heater wireUp to about 1.5 mm*Not typical*Not typical*
Automotive wire4622, typically up to 1 mm²**Typically 1–2 mm²**Typically over 2 mm²**
Jacketing
Everflon™ FEP grade4610X46084603
Multicore cable jacketsApplicable*Applicable*Special use*
Heater cable jacketsApplicable*Applicable*Special use*
Coaxial cable jacketsApplicable*Applicable*Special use*
Special applications and braided wireSpecial use*Special use*Special use*

* Evaluate after finished-cable testing.

** Automotive testing may use ISO 6722/LV 112 as specified by the project. MFR, dimensions and ratings are selection references.

08 Technical Guide

FEP Extrusion Defects: Melt Fracture, Weld Lines, and Cold Drawing

Melt Fracture, Weld Lines, and Tooling Surfaces

Melt fracture creates defects on the internal and external surfaces of the insulation or jacket, weakening the coating and introducing stress concentrations. When the tip or die experiences excessive shear rates at specific melt temperatures, melt temperature can be adjusted or extrusion speed reduced within applicable process limits. If weld lines are weak, check melt pressure at the tip, and evaluate smaller die and tip combinations if necessary. Tooling contact surfaces must remain smooth, avoiding nicks or scratches.

Cold Drawing, Preheating, and Concentricity

Low or non-uniform melt temperatures can cause excessive cold drawing, reducing the hoop or transverse properties of the coating layer. Appropriate Draw Down Ratio (DDR) and Draw Ratio Balance (DRB) help improve performance. Insufficient conductor preheating, coating eccentricity, or exposure to silicone oils and hydrocarbon fluids can also lower crack resistance.

09 Technical Guide

Cable Application Considerations: Conductor Size, Cooling Shrinkage, and Thermal Cycling

When evaluating whether FEP is suitable for specific cables, factors such as conductor size, structure, crack-promoting media, mechanical action, and thermal cycling should be comprehensively considered.

Cooling Shrinkage and Coating Stress

Volumetric shrinkage occurs when FEP transitions from the molten state to the solid state, with a volume change of approximately 30% serving as a reference for selection comparison. This induces circumferential and longitudinal stresses in the insulation layer, which has a more pronounced effect on larger cables.

Conductor Shape and Surface

Smooth circular conductors typically generate less stress concentration. Non-circular or irregular surfaces may form crack initiation points, including jackets outside braided shields, fine-wire heating elements, stranded wires, and flat or elliptical conductors. Residual metal particles and oils from wire drawing may also reduce crack resistance.

Thermal Cycling and Current Load

Repeated temperature rises and falls subject the insulation layer to alternating stress and relaxation, increasing the opportunity for crack initiation and propagation. Lighting, power, and heating wires may heat up due to electrification, while automotive wires, oven wiring, and motor lead wires in hermetic compressors may also endure repeated ambient temperature variations.

10 Technical Guide

General Selection Guide for FEP Grades

4630 | Thin Wall for Fine Wire & High-Speed Extrusion

Higher MFR helps increase extrusion speed and improves processing convenience, making it suitable for evaluating thin-wall coatings on fine-gauge wires. For high-frequency applications, dielectric loss factor and extruder downtime required for cleaning can be factored into the comparison.

4622 | Fine Wire & Higher Line Speed

Suitable for evaluating fine wires at higher line speeds. Fluidity at processing temperatures and critical shear conditions favor higher extrusion speeds, allowing comparison of processing efficiency and crack resistance with general-purpose grade 4610. MIT folding endurance and high-frequency dielectric loss should also be compared during material selection. The two 4622 data points in Figure 1 represent reference conditions with differing folding endurances.

11 · FEP

FEP extrusion efficiency and MIT folding endurance

Scroll horizontally to see all ticks and points.

MIT folding endurance (cycles to failure, 0.2 mm film)

1,00010,000100,0001,000,000
048121620242832
4603
4608
4610
4610X
4622
4622
4630

Melt flow rate MFR (g/10 min)

2.095 mm die · 372 °C (702 °F) · 5 kg load

Figure 1 | Extrusion Efficiency and Folding Endurance. The horizontal axis represents the Melt Flow Rate (MFR), ranging from 0–32 g/10 min, tested with a 2.095 mm die at 372 °C under a 5 kg load. The vertical axis represents the MIT folding life of a 0.2 mm film on a logarithmic scale from 1,000 to 1,000,000 cycles. The figure indicates seven reference points labeled 4603, 4608, 4610, 4610X, 4622, and 4630, with 4622 having two points. The curves and data points are for grade selection and comparison; actual performance of each grade is subject to technical data sheets and finished product testing.

12 Technical Guide

General, Stress-Crack Resistant, and Special Coating Grades

4610 | General Primary Insulation

Suitable for evaluating signal, control, and communication wires with general crack-resistance requirements, typically used for AWG12 or finer conductors. Larger conductors, cable jackets, or more demanding applications should have their suitability confirmed through project testing or application experience.

4608 / 4610X | Higher Crack-Resistance Requirements

When operational experience indicates the need for higher crack resistance, these two grades can be evaluated, including wires coarser than AWG 12, or small-size wires subjected to high currents, thermal cycling, and vibration. Typical jacket applications include braided shielding coverage for coaxial and heating cables, as well as non-circular conductors, power or lighting circuits, and motor and appliance wiring subject to frequent thermal cycling. Grade selection depends on extrusion equipment and processing speed.

4603 | High Crack-Resistance Special Purpose

This selection direction features higher viscosity and lower processing speed, typically used for special-purpose evaluations. When finished product crack-resistance requirements exceed the performance provided by 4608, 4603 can be included in trial production.

Large-Size Current-Carrying Conductors

For current-carrying conductors approaching AWG 4 or coarser, high current loads, large conductor sizes, and other environmental factors must be carefully evaluated. Please complete finished product testing under expected service conditions before confirming the material.

13 · FEP

Safety in FEP melt processing

Open and use resin in well-ventilated areas. Provide local exhaust at melt-processing equipment. Avoid contaminating tobacco products with resin. Read the grade safety data sheet (SDS) and fluoropolymer handling guidance before use.

14 Technical Guide

Provide Cable Specifications and Discuss Trial Grades

When submitting technical inquiries, you may first organize the following information to facilitate the evaluation of candidate grades and trial conditions.

  • Conductor outer diameter or cross-sectional area, shape, and surface structure.

  • Primary insulation or outer jacket application, target wall thickness, and extrusion line speed.

  • Operating temperature, thermal cycling, load, and finished product test requirements.

  • Current grade, extrusion equipment, known defects, defect locations, and trial condition records.

If trial samples are already available, it is recommended to provide cross-sectional photos, minimum wall thickness, line speed and melt temperature when defects occurred, and finished product test results to help narrow down the root cause.

INQUIRY

  • Afghanistan
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antarctica
  • Antigua and Barbuda
  • Argentina
  • Armenia
  • Aruba
  • Australia
  • Austria
  • Azerbaijan
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belarus
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Bosnia and Herzegovina
  • Botswana
  • Bouvet Island
  • Brazil
  • British Indian Ocean Territory
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Cayman Islands
  • Central African Republic
  • Chad
  • Chile
  • China
  • Christmas Island
  • Cocos (Keeling) Islands
  • Colombia
  • Comoros
  • Congo
  • Cook Islands
  • Costa Rica
  • Cote D'Ivoire
  • Croatia
  • Cuba
  • Cyprus
  • Czech Republic
  • Denmark
  • Djibouti
  • Dominica
  • East Timor
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands (Malvinas)
  • Faroe Islands
  • Fiji
  • Finland
  • France, Metropolitan
  • French Guiana
  • French Polynesia
  • Gabon
  • Gambia
  • Georgia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Honduras
  • Hong Kong,China
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iran (Islamic Republic of)
  • Iraq
  • Ireland
  • Israel
  • Italy
  • Jamaica
  • Japan
  • Jordan
  • Kazakhstan
  • Kenya
  • Kiribati
  • North Korea
  • South Korea
  • Kuwait
  • Kyrgyzstan
  • Lao People's Democratic Republic
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Libyan Arab Jamahiriya
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macau
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Micronesia
  • Moldova
  • Monaco
  • Mongolia
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Pitcairn
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Reunion
  • Romania
  • Russian Federation
  • Rwanda
  • Saint Kitts and Nevis
  • Saint Lucia
  • Saint Vincent and the Grenadines
  • Samoa
  • San Marino
  • Saudi Arabia
  • Senegal
  • Seychelles
  • Sierra Leone
  • Singapore
  • Slovak Republic
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • Spain
  • Sri Lanka
  • St. Helena
  • Sudan
  • Suriname
  • Swaziland
  • Sweden
  • Switzerland
  • Syrian Arab Republic
  • Taiwan, China
  • Tajikistan
  • Tanzania
  • Thailand
  • Togo
  • Tokelau
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Turkmenistan
  • Turks and Caicos Islands
  • Tuvalu
  • Uganda
  • Ukraine
  • United Arab Emirates
  • United Kingdom
  • United States
  • Uruguay
  • Uzbekistan
  • Vanuatu
  • Vatican City State (Holy See)
  • Venezuela
  • Viet Nam
  • Virgin Islands (U.S.)
  • Wallis and Futuna Islands
  • Western Sahara
  • Yemen
  • Zambia
  • Zimbabwe
  • Montenegro
  • Serbia
  • Palestine
  • South Sudan
  • Jersey