Blog

Blog

FEP Absorption, Permeability and Weathering

Nov. 11, 2026

FEP Absorption, Permeability and Weathering
FEP

EverflonTM FEP 4610

FEP Absorption, Permeability and Weathering

Compare absorption and transmission, with film thickness and test conditions in view.

Source data, charts and compliance statements concern another manufacturer’s reference material. Renaming a grade does not establish equivalence or measured performance for Everflon FEP 4610. Curves are approximate illustrations, not engineering input.
ABSORPTION

Absorption

Most plastics absorb small amounts of contacting substances into intermolecular spaces without necessarily reacting. Slight weight gain and sometimes discoloration can result.

The source reports very low absorption: virtually none for common acids and bases up to 200°C over one year, generally less than 1% weight gain from long high-temperature solvent exposure, and typical moisture uptake below 0.01% at ambient conditions. This does not validate every medium.

PERMEABILITY

Permeability

Many gases and vapors pass through the source FEP more slowly than other thermoplastics. Total transmission generally rises with temperature, pressure and area and falls with thickness. Check normalization when comparing data.

Table 7 | Typical gas transmission (source reference)
Gascc/(m²·24 hr·atm)
Carbon dioxide25.9 × 10³
Hydrogen34.1 × 10³
Nitrogen5.0 × 10³
Oxygen11.6 × 10³

Conditions: 1 mil (about 25 μm), 25°C, ASTM D1434-75. Multiply by 0.0645 for a per-100-in² basis.

Table 8 uses 1 mil film and modified ASTM E96. Each medium is at its vapor pressure at the stated temperature.

Table 8 | Typical vapor transmission (source reference)
Medium°C°Fg/(m²·d)g/(100in²·d)
Acetic acid35956.30.41
Acetone359514.70.95
Benzene35959.90.64
Carbon tetrachloride35954.80.31
Ethyl acetate359511.70.76
Ethanol359510.70.69
F-12 refrigerant (source medium)237337224
Hexane35958.70.56
Hydrochloric acid2577<0.2<0.01
Red fuming nitric acid257716010.5
50% sodium hydroxide2577<0.2<0.01
98% sulfuric acid25772 × 10⁻⁴1 × 10⁻⁵
Water39.51037.00.40
Source rounding and conversion differences are retained, including the water row. Table 7 is pressure-normalized in atm and cannot be compared directly by magnitude with Table 8.
WATER VAPOR TRANSMISSION

Water Vapor Transmission

Figure 24 relates water-vapor transmission to thickness at 40°C (104°F), modified ASTM E96. Values are averages, not specifications. Multiply per-100-in² values by 15.5 for a per-m² basis.

Figure 24 | Water-vapor transmission vs thickness · 40°CApproximate source redraw; not measured 4610 data.
Water-vapor transmission [g/(100 in²·24 h)]
Film thickness (μm)
Approximate source redraw; not measured 4610 data.

Approximate source redraw; not measured 4610 data.

The source interchanges μm and mil headings. This version uses μm based on its paired ticks. Figure 24 and the water row in Table 8 have different thickness/conditions and are not one dataset.
WEATHERING

Weathering

After 25 years outdoors in Florida, the source material was essentially unchanged: tensile strength was unaffected and elongation apparently decreased somewhat but remained high. This is not a 4610 exposure test or service-life guarantee.

Source data, charts and compliance statements concern another manufacturer’s reference material. Renaming a grade does not establish equivalence or measured performance for Everflon FEP 4610. Curves are approximate illustrations, not engineering input. · Product and Properties Handbook: Absorption; Permeability; Water Vapor Transmission; Weathering